PENGARUH LAJU ALIRAN MASSA TERHADAP DAYA TURBIN AIR FRANCIS PADA SUB UNIT PLTA JELOK SEMARANG

Tags:

Publication Type:

Journal Article

Source:

Jurnal Teknologi IST AKPRIND, Volume 1, Issue 1, Number 1 (2008)

Keywords:

francis turbine, mass of flow rate, power turbine

Abstract:

The aim of this researche is to knowing the influence of mass flow rate to power water turbine in sub unit PLTA Jelok Semarang. The power of turbine to effect mass of flow rate and height, but this analize only mass of flow rate factor always variable in every time.This analize take a data of water flow rate during three months, December 2006 until Februari 2007 and after that doing calculation on turbine power to looking for tha effect. This analize have a conclusion tahat turbine power decrease at the moment mass of flow rate to decease at 4370 kg/s and output power at 5.323 MW in Januari 2007, on the other hand turbine power go up while mass of flow rate to be involved in go up with the bighest point mass of flow rate at 10330 kg/s while output power at 12.218 MW in Pebruari 2007.

AttachmentSize
hal-9-13-erry-gabung-ok.pdf80.14 KB

(c) 2009 Jurnal teknologi FTI IST AKPRIND